Fr. 69.00

Temporary Cardiac Assist with an Axial Pump System

Anglais · Livre de poche

Expédition généralement dans un délai de 1 à 2 semaines (titre imprimé sur commande)

Description

En savoir plus

With this book, it was not our intention to provide a complete "textbook" on axial pumps and their use as temporary cardiac assist systems. It is more a sharing of experiences with a novel left-ventricular assist system, the Hemopump, as it was developed by R. K. Wampler. This device, marketed by Johnson & Johnson Interventional Systems, has not yet been widely used and accepted in clinical practice. It was offered to us some time ago to study its applicability in the experimental setting. At the moment, it is under investigation in many centers and it is commercially available. However, as with any other cardiac assist system, the axial pump has its own advantages and limitations. Needless to say, critical analysis of such a novel device is mandatory and, therefore, we are grateful to our colleagues who were willing to contribute to this book. They present, discuss, and analyze their experimental and clinical experience with the Hemopump and focus on side-effects, deficiency and efficiency of this device which, by virtue of its simplicity is revolutionary. Leuven, Belgium, 1991 Willem Flameng v Contributors H. Reul, Ph. D. Helmholtz Institute for Biomedical Engineering at the RWTH Aachen, Pauwelstrasse 30, D-5100 Aachen, FRG R. IC. Wample~ ~. D. Nimbus ~edical, Inc. , 2890 ICilgore Road, Rancho Cordova, California 95670, USA IC. -H. Scholz, ~. D. ICliniken der Universitat Gottingen, Fachbereich ~edizin, Zentrum Innere ~edizin Abt. ICardiologie, Robert ICochstrasse 40, D-3400 Gottingen, FRG P. Wouters, ~. D.

Table des matières

Hydromechanical principles of axial pumps.- The first co-axial flow pump for human use: the Hemopump.- Effect of the Hemopump in cardiogenic shock and in the early stage of regional myocardial ischemia.- Effects of left ventricular assist using a co-axial flow pump (Hemopump) on organ blood flow during experimental cardiogenic shock.- Investigational trials of the Hemopump.- Investigational trials of the Hemopump at the Texas Heart Institute: practical issues.- Success and failure of the Hemopump: a critical analysis.- Clinical results of Hemopump support in surgical cases.- Hemopump for supported angioplasty.- Indications for the use of the Hemopump.

Détails du produit

Collaboration Flameng (Editeur), W Flameng (Editeur), W. Flameng (Editeur), Willem Flameng (Editeur)
Edition Steinkopff
 
Langues Anglais
Format d'édition Livre de poche
Sortie 26.07.2013
 
EAN 9783798509061
ISBN 978-3-7985-0906-1
Pages 80
Dimensions 165 mm x 240 mm x 5 mm
Poids 178 g
Illustrations VII, 80 p. 33 illus.
Catégories Sciences naturelles, médecine, informatique, technique > Médecine > Spécialités cliniques

Kardiologie, Herz- und Thoraxchirurgie, Medizin, allgemein, Medizinische Spezialgebiete, MEDICAL / Surgery / Thoracic, GEFÄSSCHIRURGIE, Medizin / Allgemeines, Einführung, Lexikon, Herz / Kardiologie, Herzchirurgie, Chirurgie / Herzchirurgie, Gefäßchirurgie - Gefäßoperation, Chirurgie / Gefäßchirurgie, Biomedizinische Technik

Commentaires des clients

Aucune analyse n'a été rédigée sur cet article pour le moment. Sois le premier à donner ton avis et aide les autres utilisateurs à prendre leur décision d'achat.

Écris un commentaire

Super ou nul ? Donne ton propre avis.

Pour les messages à CeDe.ch, veuillez utiliser le formulaire de contact.

Il faut impérativement remplir les champs de saisie marqués d'une *.

En soumettant ce formulaire, tu acceptes notre déclaration de protection des données.