Fr. 178.00

Left Atrial Appendage Closure - Mechanical Approaches to Stroke Prevention in Atrial Fibrillation

Englisch · Fester Einband

Versand in der Regel in 2 bis 3 Wochen (Titel wird auf Bestellung gedruckt)

Beschreibung

Mehr lesen

Percutaneous left atrial appendage (LAA) closure is an emerging technology for thromboembolic prevention in patients with atrial fibrillation (AF). The first human implantation of an LAA device occurred in 2001, and since then four devices have received CE mark approval. These devices are being widely used in Europe for LAA closure in patients who are poor candidates for long-term oral anticoagulation. In the US, the WATCHMAN device (Boston Scientific) is anticipated to receive FDA approval imminently for AF patients who are warfarin-eligible. This approval is projected to significantly expand the indications for LAA closures worldwide. Thus, the volume of procedures is anticipated to escalate.
This book discusses the epidemiology of AF as a cause of stroke; the use of LAA closure in the reduction of thromboembolism with AF; early surgical approaches and novel surgical devices for LAA closure; and current percutaneous approaches and devices available for LAA closure. The emphasis of this book is on percutaneous technical approaches and contemporary trial results on the leading devices (PLAATO, WATCHMAN, Amplatzer Cardiac Plug, and LARIAT). It also reviews unapproved devices in development, in both clinical and pre-clinical phases.

Inhaltsverzeichnis

Atrial fibrillation and stroke epidemiology.- Efficacy and limitations of warfarin, and novel oral anticoagulants with AF.- Mechanistic rationale for LAA closure with AF and stroke prevention.- LAA anatomy.- Conventional surgery for LAA closure.- The use of transesophageal echocardiography to guide percutaneous LAA closure.- The use of intracardiac echocardiography to guide procedural LAA closure.- The use of cardiac CTA to guide percutaneous LAA closure.- PLAATO device.- WATCHMAN device.- WATCHMAN: Trials and registries results.- Amplatzer Cardiac Plug (ACP) and Amulet.- ACP and Amulet: Trials and registries results.- LARIAT.- LARIAT: Trials and registries results.- Novel percutaneous LAA closure devices in clinical or pre-clinical trials.- Concomitant AF ablation and LAA closure.- Procedural complications and management.- Antiplatelet and anticoagulant strategies after LAA closure.- Device-related thrombi, residual leaks and consequences.

Über den Autor / die Autorin

Jacqueline Saw, MD, FRCPC, FACC, FSCAI Clinical Associate Professor University of British Columbia Head, VGH Cardiology Clinical Trials Research Program Director, VGH Interventional Cardiology Fellowship Vancouver General Hospital 2775 Laurel Street, Level 9 Vancouver, V5Z1M9, British Columbia Canada Saibal Kar, MD, FACC Director, Interventional Cardiology Research Cedars-Sinai Medical Center 8631 W. 3rd Street, #415E Los Angeles, CA 90048 Matthew J. Price, MD, FACC, FSCAI Director, Cardiac Catheterization Laboratory Division of Cardiovascular Diseases Scripps Clinic Assistant Professor Scripps Translational Science Institute 10666 North Torrey Pines Road, Maildrop S1056 La Jolla, CA 92037 Jacqueline Saw is the editor of Carotid Artery Stenting: The Basics (978-1-60327-313-8, 2009) and Handbook of Complex Percutaneous Carotid Intervention (978-1-58829-605-4, 2007), both of which are volumes in the Contemporary Cardiology series.

Zusammenfassung

Percutaneous left atrial appendage (LAA) closure is an emerging technology for thromboembolic prevention in patients with atrial fibrillation (AF). The first human implantation of an LAA device occurred in 2001, and since then four devices have received CE mark approval. These devices are being widely used in Europe for LAA closure in patients who are poor candidates for long-term oral anticoagulation. In the US, the WATCHMAN device (Boston Scientific) is anticipated to receive FDA approval imminently for AF patients who are warfarin-eligible. This approval is projected to significantly expand the indications for LAA closures worldwide. Thus, the volume of procedures is anticipated to escalate. This book discusses the epidemiology of AF as a cause of stroke; the use of LAA closure in the reduction of thromboembolism with AF; early surgical approaches and novel surgical devices for LAA closure; and current percutaneous approaches and devices available for LAA closure. The emphasis of this book is on percutaneous technical approaches and contemporary trial results on the leading devices (PLAATO, WATCHMAN, Amplatzer Cardiac Plug, and LARIAT). It also reviews unapproved devices in development, in both clinical and pre-clinical phases.

Produktdetails

Mitarbeit Matthew J Price (Herausgeber), Saiba Kar (Herausgeber), Saibal Kar (Herausgeber), Matthew Price (Herausgeber), Matthew J. Price (Herausgeber), Jacqueline Saw (Herausgeber)
Verlag Springer, Berlin
 
Sprache Englisch
Produktform Fester Einband
Erschienen 01.01.2015
 
EAN 9783319162799
ISBN 978-3-31-916279-9
Seiten 300
Abmessung 163 mm x 18 mm x 242 mm
Gewicht 635 g
Illustration XI, 300 p.
Serien Contemporary Cardiology
Contemporary Cardiology
Themen Naturwissenschaften, Medizin, Informatik, Technik > Medizin > Klinische Fächer

B, Medicine, Surgery, Radiology, Cardiology, INTERNAL MEDICINE, interventional radiology, Cardiac Surgery, Cardiothoracic surgery

Kundenrezensionen

Zu diesem Artikel wurden noch keine Rezensionen verfasst. Schreibe die erste Bewertung und sei anderen Benutzern bei der Kaufentscheidung behilflich.

Schreibe eine Rezension

Top oder Flop? Schreibe deine eigene Rezension.

Für Mitteilungen an CeDe.ch kannst du das Kontaktformular benutzen.

Die mit * markierten Eingabefelder müssen zwingend ausgefüllt werden.

Mit dem Absenden dieses Formulars erklärst du dich mit unseren Datenschutzbestimmungen einverstanden.