Fr. 135.00

Molecular Parameters Indicating Adaptation to Mechanical Stress in Fibrous Connective Tissue

English · Paperback / Softback

Shipping usually within 6 to 7 weeks

Description

Read more

1 Introduction 1. 1 General Remarks The connective and supportive tissues constitute a considerable amount of the biomass in human and animal organisms. Characteristically, the osseous, car- laginous, and ?brous tissues each connect a vital part (cells) with a non-vital part, i. e. , extracellular matrix (ECM). The composition of the ECM constitutes the mechanical qualities of the respective tissue. The functional role of the bone and cartilage tissues is exhaustively discussed in the relevant literature. Whereas bone tissue provides the static and dynamic stability of the system as a whole, cartilage tissue accounts for the power transfer between bones. The articular cartilage insures a fairly friction free mobility of skeletal elements; likewise, cartilage interposed between skeletal elements allows mobility due to its reversible deformability. Under both static and dynamic con- tions, the powers transferred are remarkably large, while the ensuing mechanical force on various tissue zones varies. Tight connective tissue, especially muscle tendons and ligaments, are also part of the skeletal power transfer system. facilitating the transfer of tensile forces. The tendons of the locomotor system serve the purpose of transferring muscular - ergy to those skeletal elements to which they are attached. In this function, they are referred to as tensile tendons ("Zugsehnen"). Inseveral body parts, however, tendons appear in a peculiar mechanical situation: they pass around so-called - pomochlia, i. e. , bony pulleys. Hence, these tendons are referred to as wrap-around tendons ("Gleitsehnen").

List of contents

Introduction: Preliminary remarks; Adaptation of connective and supportive tissues to their respective functions; Parameters of functional adaptation.- Study aim: Fundamental considerations; Structure of the present study; Questions.- Anatomical structures investigated: Extensor tendons of the toes in the region of the proximal interphalangeal joint (PIP); Extensor tendons of the hand in the region of the MCP joint; The transverse ligament of the atlas; The transverse ligament of the acetabulum; Tendon and trochlea of the superior oblique muscle.- Materials and methods: Materials; Methodology of the immunohistochemical investigation.- Results: Extensor tendons of the toes; Extensor tendons of the hand in the region of the MCP joint; The transverse ligament of the atlas.- Discussion: Discussion of the method; Discussion of the present study's structure; Discussion of results; Conclusions.- Summary.- Bibliography.- Subject Index.

Summary

1 Introduction 1. 1 General Remarks The connective and supportive tissues constitute a considerable amount of the biomass in human and animal organisms. Characteristically, the osseous, car- laginous, and ?brous tissues each connect a vital part (cells) with a non-vital part, i. e. , extracellular matrix (ECM). The composition of the ECM constitutes the mechanical qualities of the respective tissue. The functional role of the bone and cartilage tissues is exhaustively discussed in the relevant literature. Whereas bone tissue provides the static and dynamic stability of the system as a whole, cartilage tissue accounts for the power transfer between bones. The articular cartilage insures a fairly friction free mobility of skeletal elements; likewise, cartilage interposed between skeletal elements allows mobility due to its reversible deformability. Under both static and dynamic con- tions, the powers transferred are remarkably large, while the ensuing mechanical force on various tissue zones varies. Tight connective tissue, especially muscle tendons and ligaments, are also part of the skeletal power transfer system. facilitating the transfer of tensile forces. The tendons of the locomotor system serve the purpose of transferring muscular - ergy to those skeletal elements to which they are attached. In this function, they are referred to as tensile tendons (“Zugsehnen”). Inseveral body parts, however, tendons appear in a peculiar mechanical situation: they pass around so-called - pomochlia, i. e. , bony pulleys. Hence, these tendons are referred to as wrap-around tendons (“Gleitsehnen”).

Product details

Authors Michae Benjamin, Michael Benjamin, S. Milz, Stefa Milz, Stefan Milz, Reinhard Putz
Publisher Springer, Berlin
 
Languages English
Product format Paperback / Softback
Released 13.06.2005
 
EAN 9783540244745
ISBN 978-3-540-24474-5
No. of pages 74
Weight 170 g
Illustrations VI, 74 p.
Series Advances in Anatomy, Embryology and Cell Biology
Advances in Anatomy, Embryology and Cell Biology
Subjects Natural sciences, medicine, IT, technology > Medicine > Non-clinical medicine

B, Medicine, Biomedical and Life Sciences, Biomedicine, general, Biomedical Research, tissue

Customer reviews

No reviews have been written for this item yet. Write the first review and be helpful to other users when they decide on a purchase.

Write a review

Thumbs up or thumbs down? Write your own review.

For messages to CeDe.ch please use the contact form.

The input fields marked * are obligatory

By submitting this form you agree to our data privacy statement.